Availability: | |
---|---|
Quantity: | |
hydrostatic liquid level gauge utilizes the linear variation of liquid height, density and pressure to convert the variation of the level into linear 4~20mADC standard signal.This liquid level gauge adopts imported highly stable sensors and temperature compensation correction technology to achieve such top features as good anti-interference, reliability and good stability.
Features:
1.High anti-interference,stability and reliability
2.Lighting-proof design
3.Customization.
Application:
hydrostatic level gauge can be widely used to measure the level and pressure of open containers with acid, alkali or non-corrosive mediums in the field of petroleum, iron and steel, metallurgy, oil, light industry, chemical industry, thermal power plants, sewage treatment and other industries.
Technical parameters:
Measuring range | 0~200m |
Accuracy | 0.5 |
Signal output | 4~20ADC, 0~20mA |
Loading resistance | 0~600Ω |
Transmitting distance | >1000m |
Working voltage | 24VDC |
Working temperature | -50~ +80 °C |
Environmental temperature | -40~ +50 °C |
Relative humidity | ≤85% |
Contacting liquid material | Stainless steel, PP, PTFE |
Installation flange | DN32 (Standard flange) |
customize | |
electrical connection | M20×1.5 |
Explosion-proof grade | Exia II CT6Ga Exd II CT6Gb |
hydrostatic liquid level gauge utilizes the linear variation of liquid height, density and pressure to convert the variation of the level into linear 4~20mADC standard signal.This liquid level gauge adopts imported highly stable sensors and temperature compensation correction technology to achieve such top features as good anti-interference, reliability and good stability.
Features:
1.High anti-interference,stability and reliability
2.Lighting-proof design
3.Customization.
Application:
hydrostatic level gauge can be widely used to measure the level and pressure of open containers with acid, alkali or non-corrosive mediums in the field of petroleum, iron and steel, metallurgy, oil, light industry, chemical industry, thermal power plants, sewage treatment and other industries.
Technical parameters:
Measuring range | 0~200m |
Accuracy | 0.5 |
Signal output | 4~20ADC, 0~20mA |
Loading resistance | 0~600Ω |
Transmitting distance | >1000m |
Working voltage | 24VDC |
Working temperature | -50~ +80 °C |
Environmental temperature | -40~ +50 °C |
Relative humidity | ≤85% |
Contacting liquid material | Stainless steel, PP, PTFE |
Installation flange | DN32 (Standard flange) |
customize | |
electrical connection | M20×1.5 |
Explosion-proof grade | Exia II CT6Ga Exd II CT6Gb |